An elevator suddenly stopping between floors can be a frightening experience, especially when passengers are unable to open the doors or reach the nearest floor. Whether it happens in a residential apartment, office building, shopping complex or hospital, an elevator entrapment situation requires immediate attention and a carefully managed response.
Knowing what to do when someone gets stuck in an elevator is important for passengers, security personnel, facility managers and building owners. A calm response, proper communication and assistance from qualified elevator technicians can help prevent unnecessary risks during an emergency.
The most important rule is simple: Never attempt to force open elevator doors or rescue trapped passengers without proper training and authorization. An elevator may be positioned between floors or could move unexpectedly if its safety systems are disturbed.
This guide explains the elevator rescue procedure, essential emergency precautions, responsibilities of building management and preventive measures that can improve passenger safety.
Understanding Elevator Entrapment and the Emergency Rescue Procedure
Elevator entrapment occurs when passengers are unable to leave an elevator because it has stopped operating normally or its doors cannot open through the regular controls.
An elevator may stop because of a power interruption, electrical fault, door malfunction, safety-device activation or another technical problem. Although the situation can cause anxiety, modern elevators incorporate safety mechanisms designed to reduce risks during abnormal operating conditions.
However, passengers should never assume that an elevator is safe to exit simply because it appears close to a floor.
A proper elevator rescue procedure involves communicating with trapped passengers, contacting the appropriate emergency response team, assessing the elevator’s condition and arranging a controlled rescue by authorized personnel.
1. Why Do People Get Stuck in an Elevator?
Understanding the possible reasons behind elevator entrapment helps building management respond more effectively and identify recurring technical problems.
Power Failure or Electrical Interruption
An interruption in the main electrical supply can stop an elevator during operation. Depending on the elevator’s configuration, an Automatic Rescue Device (ARD) may operate using backup power to move the elevator to a suitable landing and allow passengers to exit.
If the rescue device does not operate as expected, qualified technicians should investigate the issue.
Elevator Door Malfunction
Elevator doors rely on sensors, electrical controls and mechanical components to function correctly. A faulty door sensor, damaged door operator or obstruction in the doorway may prevent normal operation.
Control System or Mechanical Fault
Elevators depend on coordinated control systems and mechanical components. A malfunction in a control panel, drive system, safety circuit or another component may cause the elevator to stop.
Overloading or Improper Passenger Behaviour
Exceeding the elevator’s rated capacity can activate safety mechanisms or interfere with normal operation. Repeatedly pressing buttons, interfering with doors or jumping inside an elevator can also create operational problems.
Safety Device Activation
Elevators include protective systems designed to stop operation when certain abnormal conditions are detected. A safety-related stoppage should always be investigated rather than bypassed.
2. What Should You Do If You Are Stuck Inside an Elevator?
If an elevator stops unexpectedly and you cannot exit, follow these precautions.
Step 1: Stay Calm and Avoid Panic
Remain calm and avoid sudden movements. Panic can make it harder to communicate and follow instructions.
Modern elevators are designed with multiple safety features. A stopped elevator does not automatically mean that the cabin is falling or that passengers are in immediate danger.
Step 2: Press the Emergency Alarm Button
Locate and press the emergency alarm button inside the elevator. This may activate an alarm that alerts people outside the cabin.
If an emergency intercom or telephone is available, use it to contact building security or the designated emergency response team.
Step 3: Contact Building Security or Management
Inform the building’s security desk, facility manager or maintenance team about the situation.
Provide the following information:
- Building name and elevator location.
- Elevator number, if available.
- Number of passengers inside.
- Approximate floor where the elevator stopped, if known.
- Whether anyone is injured or requires medical assistance.
- Whether there is smoke, unusual heat or another immediate hazard.
Clear information helps the response team understand the situation and arrange suitable assistance.
Step 4: Do Not Force the Elevator Doors
Never attempt to pull, push or pry open elevator doors.
Even if the doors appear slightly open, the cabin may not be aligned with the landing. Attempting to exit can expose passengers to the elevator shaft or a sudden movement of the elevator.
Wait until authorized personnel confirm that it is safe to leave.
Step 5: Do Not Attempt to Climb Out
Do not climb through partially opened doors, use the elevator ceiling exit or attempt to reach another floor independently.
The space between the elevator cabin and landing can present serious fall and crushing hazards.
Step 6: Conserve Your Mobile Phone Battery
If emergency communication equipment is unavailable, use your mobile phone to contact building management or emergency services.
Keep the phone available for important calls instead of using it continuously for non-emergency activities.
Step 7: Follow the Instructions of the Rescue Team
Once qualified technicians or emergency responders arrive, listen carefully and follow their instructions.
Do not interfere with rescue activities or attempt to operate elevator controls.
3. What Should Building Management Do During an Elevator Emergency?
Building management plays an important role in coordinating an elevator emergency. A quick and organized response can reduce confusion and help passengers receive assistance without unnecessary delays.
Step 1: Identify the Affected Elevator
Confirm which elevator has stopped and determine its location within the building.
Security personnel should check the elevator identification number, building section and reported floor. They should also establish communication with passengers wherever possible.
Step 2: Establish Continuous Communication
Maintain communication with the trapped passengers through the emergency intercom or another available communication method.
Reassure them that assistance has been contacted and instruct them not to force the doors or attempt to exit independently.
Regular communication is especially important when children, elderly passengers or people with disabilities are inside.
Step 3: Contact the Elevator Maintenance Provider
Immediately inform the elevator manufacturer’s service team or authorized maintenance provider.
Share the available information about the incident, including the number of passengers, elevator location and any reported medical or safety concerns.
Request assistance from technicians who are qualified to handle the particular elevator model.
Step 4: Arrange Emergency Assistance When Necessary
If a passenger is injured, experiencing a medical emergency or exposed to an immediate hazard, contact the appropriate emergency services without waiting for routine maintenance support.
Building management should provide responders with clear access to the affected elevator and relevant building information.
Step 5: Keep Unnecessary People Away
Restrict access to the affected elevator and prevent unauthorized individuals from attempting a rescue.
Place appropriate warning notices at the affected landing areas and guide other occupants towards alternative elevators or staircases, where safe.
Step 6: Coordinate With Authorized Rescue Personnel
The actual rescue should be performed by appropriately trained and authorized elevator technicians or emergency responders following the equipment-specific procedure.
Building staff should not independently operate electrical isolation switches, manually move the elevator, open landing doors or bypass safety circuits.
Step 7: Record the Incident
After the passengers have been safely assisted, document the incident.
The record should include:
- Date and time of the incident.
- Elevator identification and location.
- Number of passengers involved.
- Reported symptoms or injuries.
- Time when assistance was contacted.
- Arrival time of the service team.
- Nature of the technical issue, if established.
- Corrective actions taken.
These records help building management identify repeated failures and improve future emergency preparedness.
4. How Does a Professional Elevator Rescue Procedure Work?
An elevator rescue is a technical operation that requires knowledge of the elevator’s design, safety systems and operating conditions.
The procedure may differ depending on whether the elevator is traction-based, hydraulic, machine-room-less or equipped with an Automatic Rescue Device.
The following describes the general stages of a controlled rescue. It is intended to explain the responsibilities of qualified personnel, not to provide a do-it-yourself rescue method.
Stage 1: Initial Situation Assessment
Authorized technicians assess the elevator’s reported condition and establish communication with passengers.
They determine the number of people inside, the approximate position of the elevator and whether any medical or environmental emergency exists.
Stage 2: Technical Evaluation
The technical team identifies the elevator model and evaluates its available safety systems, power status and reported fault conditions.
The team follows the manufacturer’s instructions and the applicable safety procedures for that specific installation.
Stage 3: Securing the Elevator
Before any rescue activity, qualified personnel establish the required safe condition of the elevator.
Depending on the system and situation, this may involve controlling the power supply, preventing unintended movement and applying the appropriate isolation procedures.
The exact steps must be determined by authorized personnel.
Stage 4: Determining the Suitable Rescue Method
The rescue team evaluates the elevator’s position and condition to determine the appropriate extraction method.
The rescue approach must account for the cabin’s position relative to the landing, the condition of the doors and the possibility of unexpected movement.
If a safe rescue cannot be established, the team must stop and arrange an appropriate specialist response.
Stage 5: Controlled Passenger Evacuation
Passengers are assisted through the designated safe exit under the direction of qualified rescue personnel.
The rescue team provides instructions and helps passengers leave the cabin without unnecessary movement or exposure to the elevator shaft.
Stage 6: Post-Rescue Safety Inspection
The elevator should remain out of service until the responsible technical team has investigated the fault, completed necessary corrective work and confirmed that the equipment is safe to operate.
Appropriate warning signs should remain in place while the elevator is unavailable.
5. Important Safety Precautions During Elevator Rescue
Elevator rescue should never be treated as an ordinary door-opening activity. Incorrect actions can turn a manageable entrapment incident into a serious accident.
Never Open Elevator Doors Without Authorization
Elevator landing doors and cabin doors are connected to safety systems. Opening them without confirming the cabin’s position can expose people to the shaft.
Never Enter the Elevator Shaft
The elevator shaft contains moving equipment, cables and other mechanical components. Entry requires specialized training, authorization and appropriate safety controls.
Never Attempt to Move the Elevator Manually
Moving an elevator without following the equipment-specific rescue procedure can cause unexpected movement or create additional hazards.
Never Bypass Safety Devices
Safety circuits, interlocks and protective systems must not be disabled as a shortcut during rescue.
Never Restart an Elevator Without Technical Assessment
Repeatedly switching the elevator on and off without identifying the underlying problem may create further risks.
Only qualified personnel should determine whether a reset or another technical intervention is appropriate.
Keep Passengers Away From the Landing Doors
People waiting outside should maintain a safe distance from the elevator entrance and follow instructions from building management and emergency personnel.
6. What If the Elevator Has an Automatic Rescue Device (ARD)?
An Automatic Rescue Device (ARD) is a safety feature designed to help move an elevator to a suitable landing when the main power supply fails.
Depending on the elevator design, the device uses backup electrical power to enable a controlled rescue movement and allow passengers to leave at a landing.
How Does an ARD Work?
When the main power supply is interrupted, the ARD detects the loss of normal power and initiates its programmed rescue sequence, subject to the system’s operating conditions.
The device may use backup power to move the elevator to an appropriate floor. The doors can then open according to the elevator’s designed safety logic.
Does Every Elevator Rescue Itself Automatically?
No. An ARD is not a guarantee that every elevator stoppage will result in automatic passenger evacuation.
Its operation depends on the equipment configuration, battery condition, system health and the nature of the fault.
For example, a mechanical obstruction or certain safety-system faults may prevent the rescue operation from completing.
Why Is Regular ARD Testing Important?
Regular inspection and testing help identify problems with backup batteries, electrical connections, control components and rescue functionality.
Building owners should ensure that ARD-related maintenance is included in the appropriate elevator service and inspection arrangements.
7. How Can Building Owners Prevent Elevator Entrapment?
Although every possible elevator stoppage cannot be eliminated, preventive maintenance and emergency preparedness can help reduce avoidable incidents.
Schedule Regular Elevator Maintenance
Follow the elevator manufacturer’s recommended maintenance schedule and the applicable legal and technical requirements.
Qualified technicians should examine critical electrical, mechanical and safety components.
Inspect Elevator Doors and Sensors
Door sensors, door operators and related components should be checked regularly to identify abnormalities that may affect normal elevator operation.
Check Emergency Communication Systems
Emergency alarms, intercoms, emergency telephones and other communication facilities should be kept operational.
Passengers must have a reliable way to request assistance when an elevator stops.
Maintain the Automatic Rescue Device
Where an ARD is installed, its backup power and operation should be checked according to the manufacturer’s recommendations and applicable requirements.
Display Emergency Contact Information
Provide clear emergency contact details inside elevators and at appropriate building locations.
This allows passengers to reach the responsible personnel without searching for assistance.
Train Security and Facility Management Staff
Security guards, building supervisors and facility managers should understand their responsibilities during an entrapment incident.
Training should cover passenger communication, emergency escalation, access control and coordination with authorized technical teams.
Conduct Elevator Emergency Mock Drills
Periodic awareness sessions and suitable mock drills help building personnel understand the correct response to elevator emergencies.
These exercises should focus on communication, escalation and coordination rather than encouraging untrained staff to perform technical rescues.
8. When Should an Elevator Be Used Again After a Rescue?
An elevator should not automatically return to service immediately after passengers have been rescued.
The original cause of the stoppage must be investigated by the responsible technical team.
Technical Fault Investigation
Technicians should assess the elevator’s condition, review relevant fault indications and identify the reason for the interruption.
Necessary Repairs and Corrective Actions
Any defective components or safety-related issues should be addressed before the elevator is considered for normal operation.
Safety Confirmation
The responsible elevator service provider should complete the necessary checks and confirm that the equipment is suitable for returning to service.
Building Management Approval and Documentation
Building management should maintain records of the incident, technical findings and completed corrective work.
The elevator should remain unavailable until the required technical clearance has been provided.
9. Why Elevator Safety Awareness Is Important for Every Building
Elevator safety is a shared responsibility involving passengers, building owners, maintenance providers and facility management teams.
Even a well-maintained elevator can experience an unexpected operational interruption. What matters is how effectively the situation is managed.
Passengers should know how to request help. Security personnel should know whom to contact. Building managers should maintain an emergency response plan, and qualified elevator technicians should handle technical rescue activities.
A proactive approach to maintenance, emergency communication and passenger awareness can help create a safer environment in residential and commercial buildings.
How Cube Elevators Supports Better Elevator Safety
At Cube Elevators, we believe that elevator performance and passenger safety go hand in hand. A reliable elevator installation requires appropriate equipment, professional technical support and a well-planned maintenance approach.
Whether you are planning a new elevator installation or looking for support with an existing elevator system, understanding the importance of safety features and regular maintenance is essential.
Our elevator solutions are designed to address the requirements of residential and commercial buildings, with attention to functionality, performance and passenger convenience.
Building owners and property managers should prioritize:
- Suitable elevator selection based on building requirements.
- Proper installation and commissioning.
- Regular preventive maintenance.
- Functional emergency communication facilities.
- Appropriate safety features and rescue arrangements.
- Timely attention to technical issues.
Looking for professional elevator solutions or maintenance support? Contact Cube Elevators to discuss your building’s elevator requirements and explore suitable solutions.
Frequently Asked Questions About Elevator Rescue Procedures
1. What should you do when someone gets stuck in an elevator?
Stay calm and use the elevator’s emergency alarm or intercom to contact building management. Inform security personnel about the situation and wait for authorized rescue assistance. Never force the doors or attempt to climb out.
2. What is the correct elevator rescue procedure?
The general elevator rescue procedure involves communicating with passengers, assessing the situation, contacting the authorized elevator service provider, securing the elevator and performing a controlled rescue. A post-rescue technical inspection is also necessary before the elevator returns to service.
3. Is it safe to open elevator doors when the lift is stuck?
No. Opening elevator doors without confirming the cabin’s position can expose passengers to serious fall and crushing hazards. Only appropriately trained and authorized personnel should open the doors during a rescue.
4. Can passengers escape from an elevator between floors?
Passengers should not attempt to escape independently. Even if the elevator appears close to a landing, the cabin may not be correctly aligned. They should remain inside and wait for authorized assistance.
5. How long does it take to rescue someone trapped in an elevator?
The rescue time depends on the elevator’s condition, the location of the cabin, the nature of the fault and the availability of qualified rescue personnel. Building management should contact the service provider immediately and escalate any medical or life-threatening emergency to emergency services.
6. What causes an elevator to stop between floors?
Common causes include electrical interruptions, control-system faults, door malfunctions, mechanical problems and safety-device activation. A qualified technician must investigate the actual cause.
7. What happens if the power goes out while someone is inside an elevator?
The elevator may stop temporarily. If an Automatic Rescue Device is installed and functioning under the existing conditions, it may move the cabin to a suitable landing. If it does not, passengers should use the emergency communication facility and wait for authorized assistance.
8. What is an Automatic Rescue Device in an elevator?
An Automatic Rescue Device (ARD) is a backup system designed to move an elevator to a suitable landing during a main power failure, using an alternative power source, subject to the equipment’s design and operating conditions.
9. Can security guards rescue someone stuck in an elevator?
Security guards should coordinate the emergency response, communicate with passengers, contact the elevator maintenance provider and keep unauthorized people away. Technical rescue should be handled by trained and authorized personnel.
10. Should an elevator be used immediately after an emergency rescue?
No. The elevator should remain out of service until the cause of the stoppage has been investigated, necessary corrective work has been completed and the responsible technical team has confirmed that it is safe to operate.
11. Does regular elevator maintenance prevent entrapment?
Regular maintenance helps identify potential faults and maintain the performance of safety-related components. However, it cannot guarantee that every unexpected elevator stoppage or entrapment will be prevented.
12. What emergency equipment should an elevator have?
Depending on applicable requirements and the elevator design, important safety provisions may include an emergency alarm, intercom or emergency communication system, emergency lighting, Automatic Rescue Device and other required safety mechanisms.
13. What should building management do after an elevator entrapment incident?
Building management should document the incident, obtain the technical findings, ensure that necessary repairs are completed and keep the elevator out of service until its safe operation has been confirmed.
14. Who is responsible for elevator rescue during an emergency?
Building management is responsible for coordinating the emergency response and contacting the appropriate service provider. The actual technical rescue should be conducted by appropriately trained and authorized elevator technicians or emergency responders.
15. How can elevator entrapment incidents be reduced?
Regular maintenance, inspection of safety components, functional emergency communication systems, ARD testing where applicable, staff training and passenger awareness can help reduce avoidable elevator incidents.
Final Note: Passenger safety should always be the first priority during an elevator emergency. Never attempt an unauthorized rescue. Contact qualified elevator professionals and follow the appropriate emergency response procedure.